RCEL Series Remote Control RCEL Series Electric Actuators are engineered to provide efficient, high performance automation of quarter turn valves. The RCEL Series has improved reliability incorporating all the best features. The maximum torque output range is 521 inch lbs. to 21,700 inch lbs. The RCEL actuators are CSA C/US approved in 120VAC models. The RCEL actuators have a number of options. For more information on the RCEL electric actuator refer to the RCEL datasheet in the product section of our website. |
|

- Standard enclosure IP-67, NEMA 4, 4X.
- Squirrel cage, totally enclosed motor
- Standardized and color-coded wiring
- Manual override hand/auto declutch lever, automatic reset when motor is energized
- Handwheel designed for safe, efficient operation
- Mounting standardized to ISO-5211; removable drive bushing can be machined to match valve stem
- Wormgear drive for longer life and low maximum noise level of 50dB
- Indicator top mounted for continuous visual indication of valve position
- 20 watt internal heater to minimize condensation due to temperature and humidity changes
- Cam actuated, end of travel limit switches are easily adjusted to de-energize actuator for precise valve position
- Torque switch is cam actuated and factory set to provide over torque protection for valves, available in size RCEL-15 thru RCEL-250
- Mechanical limit stops designed to prevent over-travel of quarter turn applications
- Valve backdrive is prevented by a rolled steel wormgear and aluminum bronze wormwheel
- CSA C/VS Approval on 120 VAC only.

|
EXP |
Explosion & Water Proof Enclosure: Class I C&D/ Class II E, F & G. Exd IIB T4 IP67 |
|
|
|
DCM |
24 VDC Motor (RCEL 6 thru RCEL 28) |
|
|
|
ACM |
24 VAC Motor (RCEL 6 thru RCEL 28) |
|
|
|
ALS |
Auxillary Limit Switches 2 SPDT switches (6 aux switches max) |
|
|
|
EXT |
Extended Travel Angle 120° to 360° (RCEL 6 thru RCEL 100) |
|
|
|
LCU |
Local Control Unit (NEMA 4) local/remote selector switch open/stop/close selector switch |
|
|
|
|
PIU |
1K Ohm Feedback Potentiometer |
|
|
|
CPT |
Current Position Feedback Transmitter 4-20mA DC output |
|
|
|
|
|
DCT |
VDC Position Feedback Transmitter 1-5VDC, 0-5VDC and 0-10VDC |
|
|
|
PCU |
Proportional Control Unit: 4-20mA, 1-5VDC or 0-10VDC input |
|
|
|
|
|
IMS |
Integral Motor Starter - includes reversing contactors and step down transformers. |
|
|
|
CLC |
Repeat Cycle Timer for cycle length control |
|
|
|
|
|
ATS |
Auxiliary Torque Switches 2 SPDT switches (RCEL 15 thru RCEL 250) |
STANDARD SPECIFICATIONS
|
Enclosure |
Watertight IP67, Nema 4, 4x |
|
Ambient Temp. |
From -20º to +158º Fahrenheit 300º Fahrenheit for 1 hour |
|
Power Supply |
120/220VAC 1-Phase 380/440VAC 3-Phase |
|
Control Power |
110/220VAC 1-Phase, 50/50Hz |
|
Duty Cycle |
See Performance Chart |
|
Torque Switches |
(2) Open/Close (RCEL-15 thru RCEL-250) |
|
Limit Switches |
(2) Open/Close, 250 VAC 16A Rating |
|
Stall Protection |
Internal Thermal Protection Open 300ºF/Close 207ºF |
|
Travel Angle |
90º ± 5º |
|
Indicator |
Continuous Position Indicator |
|
Manual Override |
HAND/AUTO Declutching Mechanism |
|
Self Locking |
Provided by means of Worm Gearing |
|
Mechanical Stops |
External Adjustable Screws |
|
Space Heater |
20Watt (24/120/220 VAC and 24 VDC) Anti-Condensation |
|
Conduit Entries |
Two 3/4" NPT. |
|
Lubrication |
Grease Moly (EP) Type |
|
Materials |
Steel, Aluminum Alloy, Aluminum Bronze |
|
Surface Treatment |
Anodizing |
|
External Coating |
Dry Powder, Epoxy-Polyester |
|
|